SNuPE Protocol
Alert
Make sure to wear gloves, eye goggles and a lab coat during the procedure!
Instructions
- Make sure that there is enough dCTP and TTP (or dGTP and dATP) in the hot room
- Set up your PCR master mix. Remember that you need to do a reaction for dCTP and TTP for each sample
- 10xPCR Buffer 2.5uL
- 0.1M MgCl2 0.375ul
- Primer 1ul
- Taq 1ul
- dH20 - enough to bring final volume to 25 ul
- Aliquot mix into each tube and place rack on ice
- Add your DNA to tubes (DNA + dH20 needs to be 19.625 ul)
- Take PCR into hot room and add 0.5 ul of appropriate nucleotide into tube
- Cap and mix by short vortex
- Run SNuPE program on PCR machine Ð make sure lids are on TIGHT
- 95º for 1 min
- 50º for 2 min
- 72º for 1 min
- 4º for 5 min
- While this is on going, prepare spin columns. Cut off tops of eppies for collection
- Briefly vortex column and then snap off bottom and turn top a bit. Place in collection eppies
- Spin for 1 min at 700g in centrifuge
- Prepare screw top tubes for columns label tops and add 5ul of loading dye to bottom of tubes
- Place columns in screw top tubes will use these for collection of SNuPE product
- When PCR is done, put on ice and bring back to hot room
- Take off tops and discard. Add 1ul 0.5M EDTA to stop the reaction. Place new tops on PCR tubes
- Bring back to PCR machine and run the M program
- 95º for 10 min
- 4º for 5 min
- Chill on ice
- Remove tops and transfer 25 ul to the spin column. Spin for 2 min at 2.3 RPM in hot room centrifuge
- Discard column and place new top on tube. Vortex to mix up loading dye.
- SNuPEs can be placed at 4º until ready to run
- For the gel, use this recipe
# of Gels | 1 | 2 |
---|---|---|
40% Acrylamide | 3.75 mL | 5.625 mL |
5x TBE Buffer | 1 mL | 1.5 mL |
dH20 | 5.25 mL | 7.875 mL |
Urea | 4.2 g | 6.3 g |
10% APS | 100 uL | 200 uL |
TEMED | 10ul | 20ul |
- Mass Urea and dissolve in H2O first. Make sure the Urea is all dissolved before moving on.
- Set up the gel apparatus make sure that you place some parafilm underneath to prevent the gel from leaking
- After loading, place in the chamber and pour in 0.5X TBE as the running buffer
- Clean out the wells with a P1000
- Load your samples with the gel loading tips 10-15uL is enough for one gel. This leaves you some leftover in case you need to run another gel.
- Run for about 40-45 minutes at 150volts. About 2/3rds of the way down
- Take apart gel apparatus and place gel on 3M Whatman paper. Cover with saranwrap
- Place in the gel drier dry at 80º for at least 1.5 hours
- Place in autorad or phosphorimager cassette